CHAPTER 2 WIRING
2-60
Description of I/O Signals
2
(4) Command input cumulative pulse latch function
This function is enabled only for VS type.
While PA2_92 is 4 through 7 and the interrupt position detection command (input
signal: %QX*.15.10) in IQ area and interrupt input enable are turned on, an interrupt input is
detected to retain the number of input cumulative pulses at that point. This number of input
cumulative pulses is stored to pulse input cumulative value (%ID*.7) in IQ area. The value is
retained while the interrupt position detection command is turned on. In addition, the interrupt
position detection (output signal: %IX*.9.5) is turned on after the interrupt input is turned on until
the interrupt position detection command is turned off.
Deviation clear: Sequence input signal (Reference value 50)
The difference (deviation) between the command position and feedback position is zeroed.
Function
The difference (deviation) between the command position and the feedback position is zeroed
while the deviation clear signal remains turned on.
The present command position changes to the present feedback position. This is enabled while the
zero speed [NZERO] signal is turned on.
Use PA3_36 (deviation clear input form) to select either the edge or level signal.
If the edge is selected, deviation is reset at the rising edge.
The activation time must be 2 [ms] or over.
Parameter setting
To assign the deviation clear to IQ area (sequence input terminal), specify the corresponding value
("50") to the input terminal function setting parameter.
The signal is handled to be always turned off if it is not assigned to the sequence input terminal.
Relevant description
All rotation commands are ignored while the deviation clear signal is turned on.
If the deviation clear signal is turned on during servomotor rotation, the manual forward rotation
[FWD] signal and so on are ignored. The feedback position does not change even if deviation clear
is executed.
You can zero the accumulated deviation due to the mechanical stop or similar, thereby avoiding
the travel by the deviation amount that may appear when the load is released.
After deviation clear is executed, the zero deviation sequence output signal is turned on.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...