CHAPTER 2 WIRING
2-68
Description of I/O Signals
2
In-position [INP]: Sequence output signal (Reference value 2)
This signal is turned on after a positioning motion is finished.
Function
(1) Status of in-position signal
The state under position control is shown in the table below.
Factor Sequence
status
Status of in-position signal
If servo-on [S-ON] is turned off
Free-run
ON
If servo-on [S-ON] is turned on
Servo lock
ON
Upon OT detection
Servo lock
ON
At deviation clear
Servo lock
ON
If forced stop [EMG] is turned off
Zero speed
ON
Upon alarm
Free-run
OFF
Position command on VS type
Always
OFF
This signal is always turned on under speed control and torque control.
(2) In-position signal output format
PA1_33 (in-position output format) at either "0" (level) or "1" (single shot) can be set.
Parameter setting
To assign the in-position [INP] to IQ area (sequence output terminal), specify the corresponding
value ("2") to the output terminal function setting parameter.
Signal activation condition
(1) At power-on
Level: ON
Single shot: OFF
(2) During command pulse input operation
Level: The signal is turned on if conditions (A) and (B) below are satisfied.
(A) The rpm of the servomotor is within the setting of PA1_30 (zero speed range).
(B) The difference (deviation amount) between the command position (command pulse
input) and feedback position is within the setting of PA1_32 (zero deviation
range/in-position range).
Single shot: If conditions (A) and (B) above are satisfied, the signal is turned on for the time
specified at PA1_34 (In-position output time: VS type) (In-position min. OFF
time/single shot ON time: LS type) and then it is turned off.
However, if the zero deviation signal is turned off while the signal remains turned on,
the signal is forcibly turned off.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...