CHAPTER 3 OPERATION
Operation with LS Type
3-33
3
You can perform “immediate value change operation” to change the target stopping position during
immediate data operation. Change position data setting (words 8 and 9) and speed data setting (words
10 and 11) and turn the immediate value change command on during immediate data operation to
change operation. Assign the immediate value change command to the CONT signal with an input
terminal function parameter and assign change setting completion to the OUT signal with an output
terminal function parameter.
Speed
Time
[RDY]
ON
[INP]
ON
[START]
OFF
ON
OFF
ON
Speed data setting (before change)
OFF
[CSEL3, 2, 1, 0]
[SEL3, 2, 1, 0]
[OFF, OFF, OFF, OFF]
Position data setting
10000 [unit amount]
Speed data setting
50000 [
×
0.01 r/min]
Position data setting
(before change)
[OFF, OFF, OFF, OFF]
15000 [unit amount]
40000 [
×
0.01 r/min]
Immediate value change
OFF
ON
OFF
Position data
setting
(after change)
Speed data setting (after change)
Immediate value
change completion
OFF
ON
OFF
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...