CHAPTER 12 POSITIONING DATA
12-2
Settings
12
12.1 Settings
The positioning data function described in this chapter is enabled only for the LS type servo amplifier.
The servo amplifier can register 99-point positioning data.
For one positioning data, one positioning motion content shall be registered.
Each data is assigned with a number between 1 and 99 (address number).
Giving the start positioning signal by specifying an address number externally, positioning operation is
started according to the set contents.
The set contents of positioning data are as follows.
For the target position and stand still timer, the position of the decimal point can be changed by setting
the (9) [Decimal Point].
Rotation speed (speed data)
0.01 to (max. rotation speed) [r/min] (in increments of 0.01)
Target position (position data)
-2000000000 to +2000000000 (in increments of 1) [×unit amount]
Set contents of positioning data
Stand still timer (stop time)
0.000 to 65.535 [s] (in increments of 0.001) or 0.00 to 655.35 [s]
(in increments of 0.01)
Command method (status)
ABS/INC
Step mode (status)
CO (data continuation) /CEND (cycle end)
M code
00 to FF (in increments of 1)
M code output
Output at startup (during positioning)/output at completion (after
completion)
Item
Setting range
M code enable/disable
Enable/disable
①
②
③
④
⑤
⑥
⑦
⑧
NO
①
②
③
④
⑤
⑥
⑦
⑧
⑨
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...