![FujiFilm ALPHA 5 RYT-SX User Manual Download Page 251](http://html.mh-extra.com/html/fujifilm/alpha-5-ryt-sx/alpha-5-ryt-sx_user-manual_2343510251.webp)
CHAPTER 4 PARAMETER
Automatic Operation Setting Parameters
4-55
4
(4) Reference signal for shift operation homing profile (equivalent to homing profile 4 of FALDIC-
α
Series)
Upon detection of a reference signal for shift operation after the start of homing, the motion
reverses to the point ahead of the reference signal for shift operation, and then the motion
continues at the creep speed for homing to detect the reference signal for shift operation and
determine the home position.
Accurate homing (highly reproducible zero position) is realized only with the reference signal for
shift operation without using the reference signal for homing (deceleration starting signal).
[Parameter setting example]
PA2_
No. Name
Setting
Default
value
Change
06
Homing speed
500.00 [r/min]
500.00
Always
07
Creep speed for homing
50.00 [r/min]
50.00
Always
08
Starting direction for homing
0: Forward rotation
0
Power
09
Reverse traveling unit amount for
homing
0 [unit amount]
0
Always
10
Homing direction after reference signal
detection
0: Forward rotation
0
Power
11
Reference signal for shift operation
0: Home position LS
1
Power
12
Reference signal for homing
(Deceleration starting signal)
3: None
0
Power
13
Home position LS signal edge selection 0: Rising edge timing
0
Power
14
Home position shift unit amount
1000 [unit amount]
1000
Always
15
Deceleration operation for creep speed
1: Reverse rotation
is
enabled
0 Power
16
Home position after homing completion 0 [unit amount]
0
Always
17
Home position detection range
0: Always ON after homing
completion
0 Always
18
Deceleration time at OT during homing 100.0 [ms]
100.0
Always
24
Selection of operation at OT during
homing
0: Reverse rotation
0
Power
•
Because rotation reverses in the direction opposite to the OT direction upon OT detection to
detect the reference signal for homing (deceleration starting signal) and reference signal for shift
operation, homing can be secured. The reverse rotation after OT detection follows (2) OT
reference homing profile.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...