SX bus connection
(1) SX bus transmission power
ALPHA5 consumes the power of the SX bus. The power consumption of one servo amplifier SX
bus is as follows.
24VDC or lower: 30 [mA] or less
(2) Number of the ALPHA5 connecting units
The number of the ALPHA5 units connected to SX bus is up to 10 in link to each of the IN and OUT
connectors of the unit. This is because the number is limited by the module mounted on the base
board, number of devices of direct connection I/O, and wiring length, etc.
Whole wiring length must be 25 [m] or less.
By connecting a SX bus electrical repeater unit (NP2L-RP1), up to 10 units can be connected per an
electrical repeater. Up to 20 units can be connected between repeaters.
CN3
APS30
PWR
ALM
SX
SCPU32
LOADER
RUN
TERM
SLV
STOP
CPU
No.
ONL
ERR
RUN
ALM
BAT
ONL 0 1 2 3 4 5 6 7
ERR 8 9 101112131415
ONL CH1
ERR CH2
EMG +OT -OT
20
1
B/A
HP2
ONL
ERR
PE1
PH
PL
DA
CH
No.
SCPU32
LOADER
RUN
TERM
SLV
STOP
CPU
No.
ONL
ERR
RUN
ALM
BAT
ONL 0 1 2 3 4 5 6 7
ERR 8 9 101112131415
Wrap plug
Wrap plug
Max. 10 units
Up to 10 units can be also
connected on OUT port side.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...