CHAPTER 4 PARAMETER
Basic Parameters
4-11
4
PA1_13 Tuning mode selection
No. Name
Setting
range
Default
value
Change
13 Tuning mode selection
0: Auto tuning
1: Semi-auto tuning
2: Manual tuning
3: Interpolation control mode
0 Always
This parameter is enabled under position and speed control.
Select the tuning method of the servo amplifier. Refer to the following description to select the mode.
Auto tuning (default value)
In this mode, the ratio of moment of inertia of the load of the machine is always assumed inside the
amplifier and the gain is automatically adjusted to the best one. "0" is entered, too, in case of easy
tuning.
Semi-auto tuning
Use this mode if the load inertia ratio of the machine has relatively large fluctuation or the load
inertia ratio is not estimated correctly inside the amplifier.
The gain is automatically adjusted to the best one in relation to the setting of PA1_14 (load inertia
ratio).
Manual tuning
Use this mode if auto tuning and semi-auto tuning modes do not function satisfactorily. Manually
enter the load inertia ratio and various gains.
Interpolation control mode
Use this mode to adjust responses of each shaft to the command during interpolation of two or
more servomotor axes of an X-Y table or similar.
In this mode, PA1_51 (moving average S-curve time) and PA1_54 (position command response
time constant) that determine the following characteristics to commands must be entered
manually.
As well, PA1_14 (load inertia ratio) must be entered, too, manually.
The other gain adjustment parameters are automatically entered.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...