CHAPTER 3 OPERATION
3-22
Operation with LS Type
3
3.4 Operation with LS Type
This section describes the LS type (RYT
□□□□
5-LS
□
) servo amplifier.
The servo amplifier occupies 16 words of the IQ area.
3.4.1 IQ Area
Register the servo and RYS-LS/RYT-LS linear positioning in the system definition of SX-Programmer
Expert. For the registered SX bus station number, the following IQ area (I: 8 words. Q: 8 words) is
assigned.
bit
Address
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0
1
Command position/feedback position/deviation current value/
parameter read value/position data (positioning data)/LS-Z pulse
2
3
Feedback speed/speed data (positioning data)/command speed/
torque current value/motor feedback current value/peak torque/effective torque
4
Torque current value/timer data (positioning data)/feedback speed/
command speed/motor feedback current value/peak torque/effective torque
5
Alarm code/status (positioning data)
M code output/M code (positioning data)
6
-
-
-
-
CSEL3
CSEL2 CSEL1 CSEL0
Positioning address/parameter no./monitor selection/
vibration suppressing workpiece inertia (answer)
7
OUT3 OUT4 OUT5
OUT6 OUT7 OUT8
OUT9
OUT10 OUT11 OUT12 OUT13 OUT14 OUT15 OUT16
Over write
completion
Read
completion
8
9
Position data setting/parameter setting
10
11
Speed data setting
12
Acceleration time data/stand still timer
Deceleration time data/stand still timer
13
Vibration suppressing and anti resonance frequency/status & M code
Acceleration
time rate
Deceleration
time rate
14
-
-
-
-
SEL3
SEL2
SEL1
SEL0
Positioning address/parameter no./monitor selection/
vibration suppressing workpiece inertia ratio
word
15
CONT6 CONT7 CONT8
CONT9 CONT10 CONT11 CONT12 CONT13 CONT14 CONT15 CONT16 CONT17 CONT18 CONT19
Write
command
Read
command
I: 0 to 7 word Q: 8 to 15 word
Allocation of the bit data at word 7 and the bit commands at word 15 can be changed with input and
output terminal function parameters. Use SEL 3 to 0 at bits 11 through 8 of word 14 to select (switch)
the functions of words 0 to 5, bits 7 to 0 of word 6, words 8 and 9, word 12, word 13, and bit 7 to 0 of
word 14 according to the operation state.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...