CHAPTER 2 WIRING
2-82
Description of I/O Signals
2
Parameter setting
To assign the speed coincidence [NARV] signal to IQ area (sequence output terminal), specify the
corresponding value ("25") to the output terminal function setting parameter.
Relevant description
PA1_25 (max. rotation speed (for position and speed Control))
Specify the upper limit of the servomotor rotation speed which is specified with a parameter.
(Except for pulse input)
If the maximum rotation speed is exceeded due to an override or similar, the servomotor rotates at
the specified value.
Torque limit detection: Sequence output signal (Reference value 26)
The signal remains turned on while the output torque of the servomotor is at the torque limit value.
Function
The torque limit value can be changed according to conditions. For details, refer to page 2-47.
The torque limit detection (26) output is enabled in all control modes.
Parameter setting
To assign the torque limit detection to IQ area (sequence output terminal), specify the
corresponding value ("26") to the output terminal function setting parameter.
Overload warning detection: Sequence output signal (Reference value 27)
The signal is turned on if the servomotor load factor is at the reference value.
A warning can be issued before the servomotor is suddenly stopped due to an overload alarm or
similar.
Function
The signal is turned on if the load factor of the servomotor reaches the overload warning level of
PA2_70 (overload warning value).
The signal is automatically turned off if the factor falls below the overload warning level. (There is
no way to reset with a sequence input signal.)
The signal can be issued before the servo amplifier trips due to an overload alarm. Determine the
reference value while referring to the characteristics diagram specified on the next page.
Parameter setting
To assign the overload warning detection to IQ area (sequence output terminal), specify the
corresponding value ("27") to the output terminal function setting parameter.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...