![FujiFilm ALPHA 5 RYT-SX User Manual Download Page 260](http://html.mh-extra.com/html/fujifilm/alpha-5-ryt-sx/alpha-5-ryt-sx_user-manual_2343510260.webp)
CHAPTER 4 PARAMETER
4-64
Automatic Operation Setting Parameters
4
(7) Homing pattern using the stopper
[Parameter setting example]
PA2_
No. Name
Setting
Default
value
Change
06 Homing speed
500.00 [r/min]
500.00
Always
07 Creep speed for homing 50.00 [r/min]
50.00
Always
10
Homing direction after
reference signal
detection
0: Forward rotation
0
Power
11
Reference signal for
shift operation
5: Stopper
1
Power
14
Home position shift unit
amount
1000 [unit amount]
1000
Always
16
Home position after
homing completion
0 [unit amount]
0
Always
17
Home position detection
range
0: Always ON after
homing completion
0 Always
22
Detection time for
contact-stopper
50 [ms]
0
Always
23
Torque limit for
contact-stopper
30 [%]
0
Always
•
Select “5” (stopper) for the home position shift amount reference signal (PA2_11). Be sure to enter
the output torque generated upon contact with the stopper, as a torque limit for contact-stopper
(PA2_23), and enter the time between contact with the stopper and completion of homing as a
Detection time for contact-stopper (PA2_22).
(i) If the home position sift amount (PA2_14) is zero, homing is finished at the stopping
position after the detection time for contact-stopper.
(ii) If the home position shift amount (PA2_14) is other than zero, the motor moves by the
home position shift amount from the stopping position after the detection time for
contact-stopper in the reverse direction to the dead stop, and homing is finished there.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...