![FujiFilm ALPHA 5 RYT-SX User Manual Download Page 107](http://html.mh-extra.com/html/fujifilm/alpha-5-ryt-sx/alpha-5-ryt-sx_user-manual_2343510107.webp)
CHAPTER 2 WIRING
Description of I/O Signals
2-63
2
Anti resonance frequency selection 0: Sequence input signal (Reference value 57)
Anti resonance frequency selection 1: Sequence input signal (Reference value 58)
Select the anti resonance frequency, which is a vibration suppressing control function.
Function
In a spring characteristic structure such as the robot arm and transfer machine, vibration is caused
at the end of the workpiece upon sudden acceleration or deceleration of the motor. Vibration
suppressing control aims at suppression of vibration of the workpiece in such a system, thereby
realizing positioning at a shorter cycle time.
Four points through combination of anti resonance frequency selection 0 and anti resonance
frequency selection 1 can be specified.
The anti resonance point may vary according to the length of the arm and the weight of the load.
Selection of the anti resonance frequency is shown in the table below.
Anti resonance
frequency selection 1
Anti resonance
frequency selection 0
Vibration suppressing
resonance frequency
Vibration suppressing
workpiece inertia ratio
OFF OFF PA1_78
PA1_79
OFF ON PA1_80
PA1_81
ON OFF
PA1_82
PA1_83
ON ON
PA1_84
PA1_85
Parameter setting
To assign the anti resonance frequency selection 0 or anti resonance frequency selection 1 to IQ
area (sequence input terminal), specify the corresponding value ("57" or "58") to the input terminal
function setting parameter.
These signals are handled to be always turned off if they are not assigned to sequence input
signals.
In this case, PA1_78 (vibration suppressing resonance frequency 0) is always enabled.
To disable the anti resonance frequency, set the anti resonance frequency at 300.0Hz.
Because in-cycle switching of the anti resonance frequency causes a shock, switch during
stoppage without fail.
In addition, it is recommended to use PA1_52 (low-pass filter (for S-curve) time constant) in
parallel.
(a) (b)
(c)
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...