CHAPTER 3 OPERATION
Operation with LS Type
3-37
3
Positioning data operation can be continued upon a single input of start positioning
[START] with positioning of continuous numbers (continuous data operation).
For the setting method, refer to “CHAPTER 12 POSITIONING DATA.”
3.4.4 Pulse Operation
Pulse operation can be performed when either command pulse ratio 1 or 2 is turned on. Use command
pulse ratios 1 and 2 to the CONT signal with input terminal function parameters. Enter and adjust the
following parameters to perform pulse operation.
Parameter No.
Parameter name
Description
Setting range
PA1_3
Command pulse
form selection
Set the connection signal format of pulse.
0: Command pulse/direction
1: Forward/reverse pulse
2: A/B phase pulse
0 to 2
PA1_5
Number of
command input
pulses per
revolution
0:
Electronic gear is enabled.
64 to 1048576: The number of input pulses per motor
revolution
0
64 to 1048576
PA1_6
Numerator 0 of
electronic gear
1 to 4194304
PA1_7
Denominator of
electronic gear
Numerator 0 of electronic gear/denominator of
electronic gear is determined from the setting of
traveling amount of the mechanical system per each
input pulse.
1 to 4194304
PA2_54
Command pulse
ratio 1
Input signal: Enabled when the command pulse ratio 1
is turned on. Specify the multiplication of the input
pulse.
0.01 to 100.00
PA2_55
Command pulse
ratio 2
Input signal: Enabled when the command pulse ratio 2
is turned on. Specify the multiplication of the input
pulse.
0.01 to 100.00
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...