Output Wattage: 40W Max.

Universal Voltage: 120-277V , 50/60Hz

~

Output Current: 250-1400mA

Output voltage range of 11-55V

General Specifications

Input Voltage
Input Current
Input Power

Standby Input Power

Output Current
Output Voltage Range
Output Power

Number of Output Channels

RFI/EMI
Output Type

Ambient Operating Temperature Range

Input Surge Protection

Protections

120-277VAC, 50/60Hz

0.43A @ 120VAC
54W

<0.85W
Constant Current

11-28VDC ( 250-1400mA ) , 11-40VDC ( 250-1000mA ) , 11-55VDC ( 250-730mA )
40W Max. ( Figure 1 )

1 Channel

FCC Part 15A Non-Consumer
LED Class 2

Line-Neutral 3kV , Line & Neutral-Gound 6kV , Ring Wave ANSI/IEEEC62.41
Input Current Protection
Output Open Circuit Protection

Output Short Circuit Protection

Output To Ground Short Circuit Protection

250-1400mA [ TPSB 100 ( Program Box ) , Figure 1 ] ; Record New Setting On 1"x0.5" Label

This Driver Will Operate The Following LED Modules: Any LED module designed to accept input voltage range of 11-55VDC and can operate
up to current of 250-1400mA.

Battery Type

LiFePO4 6.4VDC (Part# FHSBATL2-3.2L)

Battery Capacity Available

Max. Case Temperature

3200mAh

Battery Recharge Time

12 Hours

Page 1 of 7

Driver Type

FHSAC1-UNV-40C

SPECIFICATIONS

2017-736-1 Rev B

Power Factor

>0.9
<20%

THD

5W or 10W @ Emergency Mode (Min. 180 Minutes @ 5W, Min. 90 Minutes @ 10W)

Sound Rating

A

Over Temperature Protection

Overload Protection

Dimming Controller Type / Dimming Range

0-10V / 100% - 1%,0% ( Figure 2 ) / Custom Dimming Curve / Dimmed To Off

Service Life

Approvals / Class

50,000 hours

RoHS , cURus , CEC , Dry or Damp Locations

MECHANICAL DATA

100%-1%,0%

LiFePO4

E313578

0°C to 48°C(32°F to 118.4°F)

85°C (185°F)

Compact case with side leads

MECHANICAL DATA

Case Tolerance=±0.02"

FHSAC1-UNV-40C

FHSBATL2-3.2L

LED Driver with integrated emergency backup

Meets UL 924 & NFPA 101

Test Switch Remote Mounting Distance

20' (6m) Max.

Fulham extends a limited warranty to the original purchaser or first user for a period of

from the date of manufacture when properly

5 years @ Tc 63°C

installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com.
Specifications subject to change without notice.

Summary of Contents for HOTSPOT FHSAC1-UNV-40C

Page 1: ...of 250 1400mA Battery Type LiFePO4 6 4VDC Part FHSBATL2 3 2L Battery Capacity Available Max Case Temperature 3200mAh Battery Recharge Time 12 Hours Page 1 of 7 Driver Type FHSAC1 UNV 40C SPECIFICATIONS 2017 736 1 Rev B Power Factor 0 9 20 THD 5W or 10W Emergency Mode Min 180 Minutes 5W Min 90 Minutes 10W Sound Rating A Over Temperature Protection Overload Protection Dimming Controller Type Dimming...

Page 2: ...ithout notice FHSAC1 UNV 40C SPECIFICATIONS MECHANICAL DATA 100 1 0 LiFePO4 E313578 Wall Plate FHSWLPWH 70 5 2 78 115 5 4 55 Ø12 7 0 50 84 3 31 1 Charge push to Test plate 2 2 6 32 x LG mounting screws Wall plate and screw color white with black lettering 0 06 1 6mm Ø 54 13 8mm 0 31 Max 8mm Max Panel Thickness Ø 472 Ø12mm 0 88 22 4mm Ø 36 Ø9 1mm LED Lamp Ø 3 Ø7 6mm Metal cap Mounting hole ø0 472 0...

Page 3: ...Io max Curve 10 20 30 40 50 Output Voltage V 90 82 84 86 88 Efficienc 750mA 1000mA 1250mA 1400mA 80 20 25 30 35 40 45 50 55 Output Voltage V 90 86 88 ncy 750mA 1000mA 80 82 84 20 25 30 35 40 45 50 55 Effici n Output Voltage V 1250mA 1400mA Output Voltage V Efficiency vs Output Voltage at 120Vac Efficiency vs Output Voltage at 230Vac Fulham extends a limited warranty to the original purchaser or fi...

Page 4: ...50 60 70 80 Io Ratio 0 0 2 4 6 8 10 12 14 16 18 20 Resistor of Ext NTC on Module Kohm 60 70 80 90 100 110 tio Io vs Tcase driver 0 10 20 30 40 50 50 60 70 80 90 100 Io Rat Tcase C 0 95 1 00 r Power Factor Vs Output Power 277V 60Hz 0 75 0 80 0 85 0 90 Power Factor 230V 50Hz 120V 60Hz 20 25 30 35 40 Output Power W Fulham extends a limited warranty to the original purchaser or first user for a period...

Page 5: ...mergency LED light source illuminates as intended A full discharge test shall be conducted once a year the LED light source shall illuminate for a minimum of ninety 90 minutes for the 10W load Dip Switch 1 is set to the ON position or one hundred eighty 180 minutes for 5W load Dip Switch 1 is set to the OFF position If Dip Switch 2 Self Diagnostic Switch is set to the ON position The self diagnost...

Page 6: ...iver Status Mode Solid Green System OK AC OK Self diagnostic Enabled or Disabled Slow Flashing Red 4s on 1s off Battery not detected check battery switch or connection Flashing Red 1s on 1s off Battery Failure replace battery Flashing Green 1s on 1s off Self Diagnostic test underway Fast Flashing Red 0 1s on 0 1s off Abnorm al driver perform ance replace driver Very Slow Flashing Red 4s on 4s off ...

Page 7: ...ions and at heights where it will not readily be subjected to tampering by unauthorized personnel yellow black and white leads IMPORTANT A switched or un switched AC power source of 120VAC to 277VAC is acceptable for the black lead only TESTING SYSTEM The emergency battery requires a minimum charge time of one 1 hour before testing the circuit A minimum of twelve 12 hours is required for a full ch...

Reviews: