CHAPTER 2 WIRING
2-20
Configuration
2
IQ area (VS type)
bit
Address
15 14
13
12 11 10 9 8 7 6 5 4 3 2 1 0
0
1
Command position (PC
←
servo amplifier)
2
3
Feedback position (PC
←
servo amplifier)
4
Feedback speed (1 word) /parameter current value (PC
←
servo amplifier)
5
Torque (1 word) /parameter current value (PC
←
servo amplifier)
6
Position data sampling timing (PC
←
servo amplifier)
7
Pulse input cumulative value (PC
←
servo amplifier)
8
RDY INP
Alarm
detection
Zero
deviation
Zero speed
Homing
completion
Torque
limit
detection
Data error
Forced
stop
detection
Z-phase
signal
detection
Toggle
error
ALM4 ALM3 ALM2 ALM1 ALM0
9
Toggle
answer 0
Toggle
answer 1
CONT 1
Through
CONT 2
Through
CONT 3
Through
CONT 4
Through
CONT 5
Through
internal
command
pulse zero
Position
preset
response
Deviation
over
Interrupt
position
detection
CSEL
2
CSEL
1
CSEL
0
Over write
completion
Read
completion
10
11
Position command (PC
→
servo amplifier)
12
Speed command (1 word) /write parameter reference value (PC
→
servo amplifier)
13
Torque command (1 word) /write parameter reference value (PC
→
servo amplifier)
14
S-ON FWD REV
ORG RST
Position
preset
Position
control
Torque
control
Parameter no. reference value
word
15
Toggle
monitor 0
Toggle
monitor 1
Position
command
operation
EMG
Z-phase
detection
command
Interrupt
position
detection
command
Interrupt
input
enable
Deviation
clear
Free-run
CONT
6
CONT
7
SEL
2
SEL
1
SEL
0
Write
command
Read
command
Accessing data and signals is executed according to address designation.
Address designation follows MICREX-SX specifications.
.
.
RDY %IX .
8
.
0
Feedback position
%ID
.
2
Torque command
%QW
.
13
Data assigned in IQ area can be changed using bits in SEL2, SEL1, and SEL0
(%QX
.15.4 to 2).
IQ area
SEL2 SEL1 SEL0
+4 +5 +12 +13
OFF
OFF
OFF
Feedback speed
Current torque
Speed command
Torque command
OFF
OFF
ON
Feedback speed
Current torque
Workpiece inertia
ratio
Anti resonance
frequency
ON
OFF
OFF
Read parameter PA1
Write parameter PA1
ON
OFF
ON
Read parameter PA2
Write parameter PA2
ON
ON
OFF
Read parameter PA3
Write parameter PA3
Prefix
SX station no.
Word address
Bit address
I=input Q=output
X=bit data
W=word data
D=double word data
station no.
SX station no.
SX station no.
SX station no.
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...