CHAPTER 4 PARAMETER
4-68
Automatic Operation Setting Parameters
4
PA2_31 to 34 Point detection, area detection settings
No. Name
Setting
range
Default
value
Change
31
Point detection, area
detection
0: Point detection
1: ON for positive side
2: ON for negative side
0 Always
32
Point detection, area
detection position 1
-2000000000 to 2000000000 [unit amount]
0
Always
33
Point detection, area
detection position 2
-2000000000 to 2000000000 [unit amount]
0
Always
34 Point detection range
0 to 2000000000 [unit amount]
100
Always
This parameter is enabled only for LS type.
Specify the output format of the "point detection, area detection" signal that is output as an output
signal (OUT signal).
In case of point detection setting, the signal is output if the servomotor is located nearly in the reference
value (point detection range)
In case of area setting, the signal is turned on or off if the servomotor position exceeds the reference
value. Refer to the chart below.
(1) Point detection (If PA2_31 (point detection, area detection) is 0)
The signal is turned on if the current position is nearly the position specified in the standard
parameter.
10.0 10.0
190.0 200.0 210.0
Current position
Fixed point
OFF
ON
Point detection range
(PA2_34)
Point detection, area detection position 1
(PA2_32)
Point detection, area detection position 2
(PA2_33)
(Standard parameter 64)
Summary of Contents for ALPHA 5 RYT-SX
Page 1: ...MEHT301a FUJI SERVO SYSTEM USER S MANUAL RYT SX type ...
Page 19: ...0 1 CHAPTER 0 INTRODUCTION 0 ...
Page 34: ...CHAPTER 0 INTRODUCTION 0 16 Combination between Servomotor and Servo Amplifier 0 ...
Page 35: ...1 1 CHAPTER 1 INSTALLATION 1 ...
Page 45: ...2 1 CHAPTER 2 WIRING 2 ...
Page 142: ...CHAPTER 2 WIRING 2 98 Description of I O Signals 2 ...
Page 143: ...3 1 CHAPTER 3 OPERATION 3 ...
Page 197: ...4 1 CHAPTER 4 PARAMETER 4 ...
Page 296: ...CHAPTER 4 PARAMETER 4 100 Output Terminal Function Setting Parameters 4 ...
Page 297: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5 ...
Page 329: ...6 1 CHAPTER 6 KEYPAD 6 ...
Page 371: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7 ...
Page 389: ...8 1 CHAPTER 8 SPECIFICATIONS 8 ...
Page 414: ...CHAPTER 8 SPECIFICATIONS 8 26 Dimensions of Servo Amplifier 8 ...
Page 415: ...9 1 CHAPTER 9 CHARACTERISTICS 9 ...
Page 425: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10 ...
Page 463: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 ...
Page 473: ...12 1 CHAPTER 12 POSITIONING DATA 12 ...
Page 482: ...CHAPTER 12 POSITIONING DATA 12 10 Response Time 12 ...
Page 483: ...13 1 CHAPTER 13 PC LOADER 13 ...
Page 513: ...14 1 CHAPTER 14 APPENDIXES 14 ...
Page 545: ...CHAPTER 14 APPENDIXES Service Network 14 33 14 14 8 Service Network ...
Page 546: ...CHAPTER 14 APPENDIXES 14 34 Service Network 14 ...