Appendix G Conformity with Standards
Appendix-40
2. Use Cu wire only.
3. Use Class 1 wire only for control circuits.
4. Short circuit rating
For Models FRN0001 to 0006E2
■
-2
, FRN0088 to 0115E2
■
-2
and FRN0001 to 0005E2
■
-7
:
"Suitable For Use On A Circuit Of Delivering Not More Than 100,000 rms Symmetrical Amperes, 240 Volts
Maximum when Protected by a Class J or Class CC Fuses or a Circuit Breaker Having An Interrupting Rating
Not Less Than 100,000 rms Symmetrical Amperes, 240 Volts minimum.”
For Models FRN0010 to 0069E2
■
-2
and FRN0008 to 0011E2
■
-7
:
"Suitable For Use On A Circuit Of Delivering Not More Than 100,000 rms Symmetrical Amperes, 240 Volts
Maximum when protected by Class J or Class CC Fuses.”. May be provided on the instruction manual.
For Models FRN0002 to 0044E2
■
-4
:
"Suitable For Use On A Circuit Of Delivering Not More Than 100,000 rms Symmetrical Amperes, 480 Volts
Maximum when protected by Class J or Class CC Fuses.”
For Models FRN0059E2
■
-4
or above:
"Suitable For Use On A Circuit Of Delivering Not More Than 100,000 rms Symmetrical Amperes, 480 Volts
Maximum when protected by Class J or Class CC Fuses or a Circuit Breaker Having An Interrupting Rating
Not Less Than 100,000 rms Symmetrical Amperes, 480 Volts minimum.”
5. Field wiring connections must be made by a UL Listed and CSA Certified closed-loop terminal connector
sized for the wire gauge involved. Connector must be fixed using the crimp tool specified by the connector
manufacturer.
6. All circuits with terminals L1/R, L2/S, L3/T, L1/L, L2/N, R0, T0, R1, T1 must have a common disconnect and
be connected to the same pole of the disconnect if the terminals are connected to the power supply.
Connection diagram of the three phase input type.
FRN0020E2
■
-2
□
or below
FRN0012E2
■
-4
□
or below
FRN0030E2
■
-2
□
or above
FRN0022E2
■
-4
□
or above
Connection diagram of the single phase input type.
FRN0011E2
■
-7
□
or below
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......