5.3 Description of Function Codes
5-141
FU
NCT
IO
N
C
O
DE
S
Chap 5
C21
C22 to C28
Pattern operation mode selection
Stage 1 to 7 / Timed operation
Pattern operation is a function of automatic operation according to the predefined run time, rotational direction,
acceleration/deceleration time and reference frequency.
When using this function, set the frequency setting (F01) to 10 (pattern operation).
The following operation patterns are available:
C21:Setting
Operation pattern
0
Pattern operation performed for one cycle and stopped after the cycle.
1
Pattern operation repeatedly performed and immediately stopped with a stop command
2
Pattern operation performed for one cycle and operation continued at the reference
frequency after the cycle.
3
Timed operation
■
C22 to C28 Stage 1 to Stage 7
Specify the run time for Stage 1 to Stage 7.
Press the
key three times for each function code to set the following three data.
Setting
Description
1st
Specifies the run time between 0.0 and 6000 s.
2nd
2nd: Specifies the rotational direction F (forward) or r (reverse)
3rd
3rd: Specifies the acceleration/deceleration time between 1 and 4.
1: F07/F08
2: E10/E11
3: E12/E13
4: E14/E15
If the
key is pressed to exit the function code before the three data are specified by pressing the
key three
times, no data are updated.
For any unused stage, specify 0.0 as the run time. The stage is skipped and the next stage becomes ready for
setting.
Time
Time
Reverse
direction
Time
Setting value: 0
0
Forward
direction
Output
frequency
Reverse
direction
1 cycle completed
Setting value: 1
0
Forward
direction
Output
frequency
Reverse
direction
1 cycle completed
Setting value: 2
0
Forward
direction
Output
frequency
1 cycle completed
Run command
source
Run command
source
Run command
source
2 cycle completed
2 cycles completed
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......