5.3 Description of Function Codes
5-238
[ 2 ] Master-follower operation
d71 to d78 Master-follower operation
These function codes specify various parameters required for master-follower operation.
■
Application-Defined Control (d41)
Data for d41
Function
2
Immediate synchronization mode at the start, without Z phase
3
Start after synchronization mode
4
Immediate synchronization mode at the start, with Z phase
The master-follower operation control enables the follower inverter to detect the master motor rotation with PG
signals and synchronize the follower motor with the master motor in rotation speed and position.
The master-follower operation is available in three modes: Immediate synchronization mode at the start, with Z
phase (d41 = 4) and without Z phase (d41 = 2) and Start after synchronization mode (d41 = 3).
PG signals from master motor should be fed to terminals XA, XB, and XZ, and follower motor’s ones, to terminals
YA, YB, and YZ.
Table 5.3-33 Specifications of Master-follower operation
Item
Specifications
Remarks
Control
Speed control range
under V/f control with speed
sensor
1:100
4-pole motors and PGs with 1024 P/R
Speed reduction ratio = 1:1
During running at constant speed
Speed control range under
vector control with speed
sensor
1:1500
Position control accuracy
±
2
°
Electrical
requirements Input pulse rate
10 p/s to 100 kp/s *
Maximum wiring length: 100 m (328 ft) *
When using quadrature encoders
* For PGs with an open collector output, the input pulse rate is 30 kp/s or below and the maximum wiring length is
20 m (66 ft).
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......