1.1 Acceptance Inspection (Nameplates and Inverter Type)
1-2
The FRENIC-Ace is available in four different drive modes--ND (Normal Duty), HD (Heavy Duty), HND (High,
Normal Duty), and HHD (High, Heavy Duty). One of these modes should be selected to match the load property of
your system. Specifications in each mode are printed on the main nameplate.
ND mode
: Designed for general load applications.
Overload capability: 120% for 1 min.
HD mode
: Designed for heavy duty load applications.
Overload capability: 150% for 1 min.
HND mode : Designed for general load applications.
Overload capability: 120% for 1 min.
HHD mode : Designed for heavy duty load applications.
Overload capability: 150% for 1 min. and 200% for 0.5 s.
SOURCE
: Number of input phases (three-phase: 3PH), input voltage, input frequency, input current
OUTPUT
: Number of output phases, rated output voltage, output frequency range, rated output capacity,
rated output current, and overload capability
SCCR
: Short-circuit capacity
MASS
: Mass of the inverter in kilogram
SER. No.
: Product number
6 8 A 1 2 3 A 0 5 7 9 E BB 6 0 1
Production week
This indicates the week number that is numbered
from 1st week of January.
The 1st week of January is indicated as '01'.
Production year: Last digit of year
Product version
: Compliance with European Standards (See Appendix G Section G-1)
: Compliance with UL Standards and Canadian Standards (cUL certification)
(See Appendix G Section G-2)
: Compliance with the Radio Waves Act (South Korea) (See Appendix G Section G-3)
: Compliance with Russian Standards
If you suspect the product is not working properly or if you have any questions about your product, contact your
Fuji Electric representative.
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......