Operation Mode (J66)
J66 specifies the inverter’s operation condition under
which the overload stop function is activated.
Carefully make this setting so as not to activate the
overload stop function when it is not necessary.
J66 data
Operation mode
0
Enabled during constant speed
and deceleration time.
1
Enabled during constant speed
2
Enabled always
■
Timer (J67)
Apply the timer (J67) to prevent the start of the overload stop function due to the instantaneous, unintended load
fluctuation. The overload stop function is activated when the operation condition has continued for specified timer
J67. (if J65=1, 2).
■
Enable overload stop - “OLS” (E01 to E05 = 46)
Turning this terminal command ON enables the overload stop function; turning it OFF disables the function. If “OLS”
is not assigned to any terminal, the overload stop function is always valid.
[ 6 ] Brake control signal
J68 to J70
J71, J72
J95, J96
Brake control signal (Brake-release current, Brake-release frequency/speed and
Brake-release timer)
Brake control signal (Brake-apply frequency/speed and Brake-apply timer)
Brake control signal (Brake-release torque, Brake-apply conditions)
Related function code: A98: Motor 2 (Function selection)
The brake (release/apply) control signal is useful for lift application such as a hoist. This signal is adjustable with
these function codes.
It is possible to set the release and apply conditions based of these signals (current, torque and frequency/speed)
so that a hoisted load does not fall down at the start or stop of the operation, or so that the load applied to the brake
is reduced.
■
Brake control “BRKS” (E20, E21 and E27, data = 57)
This signal outputs a brake control command that releases or applies the brake.
Releasing the Brake
When the inverter output current and output frequency exceeds the specified level for the brake control signal
(J68/J69/J95) for the period specified by J70 (Brake control signal (Brake-release timer)), the inverter judges that
required motor torque is generated and turns the signal BRKS ON for releasing the brake.
This prevents a hoisted load from falling down due to an insufficient torque when the brake is released.
Function code
Name
Data setting range
Remarks
J68
Brake-release current
0.00 to 300.00%:
Set the value in percentage (%) of the
inverter rated current.
J69
Brake-release
frequency/speed
0.0 to 25.0 Hz
J70
Brake-release timer
0.00 to 5.00s
J95
Brake-release torque
0.00 to 300.00%
Only available under vector control with
speed sensor.
Note: Resolution of each function code is different from the FRENIC-MEGA and FRENIC-Multi series.
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......