![Fuji Electric FRENIC-Ace series User Manual Download Page 271](http://html1.mh-extra.com/html/fuji-electric/frenic-ace-series/frenic-ace-series_user-manual_2341846271.webp)
5.3 Description of Function Codes
5-101
FU
NCT
IO
N
C
O
DE
S
Chap 5
Data
Terminal commands assigned
Symbol
Control mode
Related function
codes
Active
ON
Active
OFF
V/f
PG
V/f
IM
CLV
IM
TC
PM
SLV
19
1019 Allow function code editing
(Data change enabled)
“WE-KP”
Y
Y
Y
Y
Y
F00
20
1020 Cancel PID control
“Hz/PID”
Y
Y
Y
N
Y
J01 to J19, J57
to J62
21
1021 Switch normal/inverse operation
“IVS”
Y
Y
Y
N
Y
C53, J01
22
1022 Interlock
“IL”
Y
Y
Y
Y
Y
F14
23
1023 Cancel torque control
“Hz/TRQ”
N
N
N
Y
N
H18
24
1024 Select link operation
(RS-485, BUS option)
“LE”
Y
Y
Y
Y
Y
H30, y98
25
1025 Universal DI
“U-DI”
Y
Y
Y
Y
Y
―
26
1026 Select auto search for idling motor
speed at starting
“STM”
Y
Y
N
N
Y
H09, d67
1030
30
Force to stop
“STOP”
Y
Y
Y
Y
Y
F07, H56
32
1032 Pre-excite
“EXITE”
N
N
Y
Y
N
H84, H85
33
1033 Reset PID integral and differential
terms
“PID-RST”
Y
Y
Y
N
Y
J01 to J19, J57
to J62
34
1034 Hold PID integral term
“PID-HLD”
Y
Y
Y
N
Y
35
1035 Select local (keypad) command
“LOC”
Y
Y
Y
Y
Y
(See Section
3.3.7)
42
1042 Activate the limit switch at start point
“LS”
Y
Y
N
N
N
J73 to J88
43
1043 Start/Reset
“S/R”
Y
Y
N
N
N
44
1044 Switch to the serial pulse receiving
mode
“SPRM”
Y
Y
N
N
N
45
1045 Enter the return mode
“RTN”
Y
Y
N
N
N
46
1046 Enable overload stop
“OLS”
Y
Y
Y
N
Y
J63 to 67
47
1047 Servo-lock command
“LOCK”
N
N
Y
N
N
J97 to J99
48
―
Pulse train input (Only for X5
terminal (E05))
“PIN”
Y
Y
Y
N
Y
F01, C30 d62,
d63
49
1049 Pulse train sign (Other than X5
terminal (E01 to E04))
“SIGN”
Y
Y
Y
N
Y
59
1059 Enable battery-driven operation
“BATRY/UPS” Y
Y
Y
Y
Y
-
60
1060 Select torque bias1
“TB1”
N
N
Y
N
N
H154 to H162
61
1061 Select torque bias2
“TB2”
N
N
Y
N
N
62
1062 Hold torque bias
“H-TB”
N
N
Y
N
N
65
1065 Check brake
“BRKE”
Y
Y
Y
N
Y
J68 to 96
70
1070 Cancel line speed control
“Hz/LSC”
Y
Y
Y
N
N
d41
71
1071 Hold line speed control frequency in
the memory
“LSC-HLD”
Y
Y
Y
N
N
72
1072 Count the run time of commercial
power-driven motor 1
“CRUN-M1”
Y
Y
Y
Y
N
H44,H94
73
1073 Count the run time of commercial
power-driven motor 2
“CRUN-M2”
Y
Y
Y
Y
N
76
1076 Select droop control
“DROOP”
Y
Y
Y
N
Y
H28
78
1078 Select speed control parameter 1
“MPRM1”
N
N
Y
Y
N
d01 to d08
79
1079 Select speed control parameter 2
“MPRM1”
N
N
Y
Y
N
80
1080 Cancel customizable logic
“CLC”
Y
Y
Y
Y
Y
E01 toE05, U81
to U90
81
1081 Clear all customizable logic timers
“CLTC”
Y
Y
Y
Y
Y
82
1082 Cancel anti-regenerative control
“AR-CCL”
Y
Y
Y
N
Y
H69
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......