7.5 Measurement of Electrical Amounts in Main Circuit
7-9
M
AI
N
TEN
AN
C
E A
N
D
IN
S
P
EC
TI
O
N
Chap
7
7.5 Measurement of Electrical Amounts in Main Circuit
Because the voltage and current of the power supply (input, primary circuit) of the main circuit of the inverter and
those of the motor (output, secondary circuit) contain harmonic components, the readings may vary with the type of
the meter. Use meters indicated in Table 7.5-1 when measuring main circuit.
The power factor cannot be measured by a commercially available power-factor meter that measures the phase
difference between the voltage and current. To obtain the power factor, measure the power, voltage and current on
each of the input and output sides and use the following formula.
■
Three-phase input
%
100
×
(A)
Current
×
(V)
Voltage
×
3
(W)
power
Electric
=
factor
Power
Table 7.5-1 Meters for Measurement of Main Circuit
Item
Input (primary) side
Output (secondary) side
DC link bus
voltage
(P(+)-N(-))
W
av
efor
m
Voltage
Current
Voltage
Current
Nam
e
of
m
eter
Ammeter
AR, AS, AT
Voltmeter
VR, VS, VT
Wattmeter
WR, WT
Ammeter
AU, AV, AW
Voltmeter
VU, VV, VW
Wattmeter
WU, WW
DC voltmeter V
Ty
pe of
m
eter
Moving iron
type
Rectifier or
moving iron
type
Digital
AC power
meter
Digital AC
power meter
Digital AC
power meter
Digital AC
power meter Moving coil type
S
ym
bol
of m
eter
It is not recommended that meters other than a digital AC power meter be used for measuring the output
voltage or output current since they may cause larger measurement errors or, in the worst case, they may
be damaged.
Figure 7.5-1 Connection of Meters
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......