![Fuji Electric FRENIC-Ace series User Manual Download Page 257](http://html1.mh-extra.com/html/fuji-electric/frenic-ace-series/frenic-ace-series_user-manual_2341846257.webp)
5.3 Description of Function Codes
5-87
FU
NCT
IO
N
C
O
DE
S
Chap 5
■
Torque limit control mode
Torque limit is performed by limiting torque current flowing across the motor.
The graph below shows the relationship between the torque and the output frequency at the constant torque
current limit.
■
Torque limiter (F40, F41, E16, E17) Data setting range: 0 to 300%; 999 (Disable)
These function codes specify the operation level at which the torque limiters become activated, as the percentage
of the motor rated torque.
Function code
Name
Torque limit feature
F40
Torque limiter 1 (Driving)
Driving torque current limiter 1
F41
Torque limiter 1 (Braking)
Braking torque current limiter 1
E16
Torque limiter 2 (Driving)
Driving torque current limiter 2
E17
Torque limiter 2 (Braking)
Braking torque current limiter 2
Although the setting range of the torque is 300%, the torque limiter determined by the overload current of
the unit internally limits the torque current output. Therefore, the torque current output is automatically
limited at a value lower than 300%, the maximum setting value.
■
Analog torque limiter (E61 to E63)
The torque limit value can be specified by analog inputs (voltage or current) through terminals [12], [C1] (C1
function), and [C1] (V2 function). Assign by Extension function selection function codes E61, E62, E63 (Terminal
[12], [C1] (C1 function), [C1] (V2 function) as follows.
E61, E62, E63 data
Function
Description
7
Analog torque limiter A
Used when analog inputs are used as torque limiters.
Input modes: 200% / 10 V or 20 mA
8
Analog torque limiter B
If these terminals have been set up to have the same data, the operation priority is given in the following order: E61
> E62 > E63
Refer to E59 on how to use terminals [C1] (C1 function) and [C1] (V2 function).
■
Torque limiter levels specified via communications link (S10, S11)
The torque limiter levels can be changed via the communications link. Communication dedicated codes S10, S11
interlock with the function codes F40, F41.
Torque
Constant torque limit
Constant output limit
Base frequency
Output frequency
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......