5.2 Function Codes Table
5-20
Code
Name
Data setting range
C
han
ge
w
hen
ru
nn
ing
D
at
a
co
py
in
g
Factory
Default
Drive control
R
el
at
ed
p
ag
e
V
/f
PG
V/
f
w
/ P
G
Tor
qu
e c
on
tro
l
PM
H154 Torque bias (Mode selection)
*5
0: Invalid
1: Digital torque bias
2: Analog torque bias
N Y
0
N N Y N N 5-190
H155
(Level 1) -300 to +300 %
N Y
0
N N Y N N
H156
(Level 2) -300 to +300 %
N Y
0
N N Y N N
H157
(Level 3) -300 to +300 %
N Y
0
N N Y N N
H158
(Mechanical loss
compensation)
0 to 300 %
N Y
0
N N Y N N
H159
(Startup timer) 0.00 to 1.00 s
N Y
0.00
N N Y N N
H161
(Shutdown timer) 0.00 to 1.00 s
N Y
0.00
N N Y N N
H162
(Limiter) 0 to 300 %
N Y
200
N N Y N N
H173 Magnetic flux level at light load
*5
10 to 100 %
Y Y
100
N N Y Y N 5-192
H180 Brake control signal
(Check-timer for brake
operation)
0.00 to 10.00 s
Y Y
0.00
Y Y Y N N 5-192
H193 User initial value
(Save) 0: Disable,
1: Save
Y N
0
Y Y Y Y Y 5-156
H194
(Protection) 0: Save enable,
1: Protected (Save disable)
Y Y
0
Y Y Y Y Y
H195 DC braking
(Braking timer at the startup)
0.00 (Disable): 0.01 to 30.00 s
Y Y
0.00
Y Y N N N 5-74
5-192
H196 Reserved *5 *9
0.001 to 9.999, 999
Y Y
999
Y Y N N N
–
H197 User password 1
(Selection of protective
operation)
0: All function codes are disclosed, but the change is not
allowed.
1: Only the function code for quick setup can be
disclosed/changed.
2: Only the function code for customize logic setting is not
disclosed/not changed.
Y Y
0
Y Y Y Y Y 5-187
H198
(Setting/check) 0000 to FFFF (Hexadecimal)
Y N
0
Y Y Y Y Y
H199 User password protection
valid
0: Disable
1: Protected
Y N
0
Y Y Y Y Y
*5: Available at ROM version 0300 or later.
*9: Factory use. Do not access these function codes.
Summary of Contents for FRENIC-Ace series
Page 20: ......
Page 32: ......
Page 92: ......
Page 94: ......
Page 452: ......
Page 490: ......
Page 504: ......
Page 508: ...8 2 Frequency Setting Section 8 4 Figure 8 2 3 Frequency Setting Section Block Diagram...
Page 520: ...8 6 Control Section 8 16 6 For PMSM Figure 8 6 9 Vector Control For PMSM Section Block Diagram...
Page 522: ...8 7 FM Output Section 8 18 8 7 FM Output Section Figure 8 7 1 FM Output Section Block Diagram...
Page 582: ......
Page 664: ...11 15 External Cooling Fan Attachments 11 60...
Page 690: ......
Page 692: ......
Page 720: ......
Page 738: ......
Page 787: ......