Maintenance 5. Joint #1
180
C12 Rev.3
Removal: Joint #1 Timing belt (M/C Cable Downward)
1.
Turn OFF the Controller.
2.
Turn the Manipulator laterally.
CAUTION
■
When turning the Manipulator laterally, there must be two or more people to
work on it so that at least one of them can support the arm while the others are
removing the bolts. Removing the bolts without supporting the arm may result
in the arm falling, bodily injury, and/or malfunction of the robot system.
3.
Remove the following covers.
Base maintenance cover
Base cover (M/C cable downward)
Connector plate (M/C cable downward)
For details, refer to
Maintenance: 3 Covers
.
4.
Disconnect the cables from the base and disconnect the
following connectors.
Connector: X11, X12, X14, BR010, BR011, X010, X020,
X040,
LED, GS01, BT1
(Hold the clip to remove.)
5.
Disconnect the following parts.
Air tubes
RJ45 connector
F-sensor connector
D-sub connector
For details, refer to
Maintenance: 5.1.3 Joint #1-Replacing the Timing Belt (M/C Cable Backward)
,
Removal steps (4) to (5), and (7).
6.
Remove the brake power supply.
Cross recessed head screws with washer: 2-M3×6
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...