Setup & Operation 4. End Effectors
C12 Rev.3
37
4. End Effectors
4.1 Attaching an End Effector
Create an end effector for your Manipulator. Flange dimensions of the wrist attached to
the end of Arm #6 is as below.
CAUTION
■
If you use an end effector equipped with a gripper or chuck, connect wires and/or
pneumatic tubes properly so that the gripper does not release the work piece
when the power to the robot system is turned OFF. Improper connection of the
wires and/or pneumatic tubes may damage the robot system and/or work piece
as the work piece is released when the Emergency Stop switch is pressed.
I/O outputs are configured at the factory so that they are automatically shut off (0)
by power disconnection, the Emergency Stop switch, or the safety features of the
robot system.
Wrist Flange
Detail of A
A
Arm #6
Attach an end effector to the end of the Arm #6 using the M5 bolts.
Layouts
When you operate the Manipulator with an end effector, the end effector may interfere with
the Manipulator body depending on the outer diameter of the end effector, the size of the
work piece, or the position of the arms. When designing your system layout, pay close
attention to the interference area of the end effector.
Compatibility with ISO flange:
To install the end effector whose mounting dimensions are designed for the ISO flange, we
provide the optional C8 ISO flange (J6). For details, refer to
Setup & Operation: 6.
Options
.
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...