Maintenance 9. Joint #5
250
C12 Rev.3
Drive boss and the motor shaft:
Hexagon socket set screws: 2-M4×4
Tightening torque: 2.5
±
0.2 N·m
Align the screws to the two flat faces of the motor shaft and fix them.
Drive boss and the pulley 1:
Hexagon socket set screws: 2-M4×4 (with a brass bushing)
Tightening torque: 2.5
±
0.2 N·m
Fix the set screws while pressing the pulley 1 to the drive boss.
The brass bushing is not necessary for the screw for the flat surface (D-cut). Set the bushing to the other
screw and then fix the screw.
4.
Put the Joint #5 motor unit inside the Arm #4.
Pass the cables of the Joint #5 motor unit to the Joint #6 motor unit
side so that the cables can be stored in the storage space.
(See the photo)
5.
Pass the timing belt around the pulley 1 and pulley 2 and fix it
temporarily.
Make sure that the teeth of the timing belt engage with these of the
pulley.
As a rough guide of temporary fixing, check that the motor unit can
be moved by hand, and it does not tilt when being pulled. If the
belt is too loose or too tight, it will not have proper tension
6.
Apply tension to the Joint #5 timing belt and fix the Joint #5 motor
unit.
Joint #5 Timing belt tension: 15 to 30 N
Bet tension meter setting value
Weight: 2.5 g/mm width × m span, Width: 6 mm, Span: 117 mm
Hexagon socket head cap bolts: 2-M4×15 (with a plain washer)
Tightening torque: 4.0
±
0.2 N·m
Regarding belt tension:
-
Jumping (position gap) may occur if the value is below the lower
limit.
-
Vibration (abnormal noise) or reduction in life of the parts may
occur if the value exceeds the upper limit.
-
When you replace with a new belt, belt extends and the belt tension
may decrease in the initial stage. Make sure to operate the robot
two to three days and check the belt tension again.
NOTE
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...