Maintenance 4. Cable Unit
C12 Rev.3
117
45.
Remove the two air tubes inside the Arm #4.
46.
Cut off the wire tie that binds the cables of the Arm #4.
47.
Loosen the bolts that fix the cable protection plate attached on the
Arm #4, and disconnect the cables.
Hexagon socket head cap bolts: 2-M4×10
48.
Remove the ground wire terminals from the cable protection plate.
Cross recessed head screws with washer: 4-M4×8
49.
Remove the Joints #5 and #6 motor units.
For details, refer to
Maintenance: 9.1 Joint #5 - Replacing the Motor
, Removal steps (4) to (8),
and
Maintenance: 10.1 Joint #6 - Replacing the Motor,
Removal steps (4) to (7).
The air tube fittings removed together with the Joint #5 motor unit will be used again. Be careful not to
lose them.