Maintenance 5. Joint #1
186
C12 Rev.3
Installation: Joint #1 Electromagnetic brake (M/C Cable Downward)
1.
Install the Joint #1 brake to the brake plate.
Hexagon socket head cap bolts: 3-M4
×
25
Tightening torque: 4.0
±
0.2 N·m
Be careful of the assembly direction of the Joint #1
electromagnetic brake. (See the photo)
2.
Mount the Joint #1 brake plate to the Joint #1 motor unit.
For details, refer to
Maintenance: 5.1.1 Joint #1 - Replacing the Motor (M/C Cable Backward)
,
Installation step (4).
3.
Install the brake power supply to the plate.
Make sure to install the brake power supply so that the cables
will be in the direction as shown in the photo.
Cross recessed head screws with washer: 2-M3×6
Tightening torque: 0.45
±
0.1 N·m
4.
Connect the M/C cable connectors.
Connector: X11, X010, BT1, BR011
5.
Install the following covers.
Connector plate (M/C cable downward)
Base cover (M/C cable downward)
Base maintenance cover
For details, refer to
Maintenance: 3 Covers
.
If you disconnected the connector BT1 in the removal steps, perform calibration.
NOTE
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...