Maintenance 3. Covers
C12 Rev.3
105
3.12 Connector Sub Plate
CAUTION
■
Do not remove the connector sub plate forcibly. It may result in damage to the
cables, disconnection, and/or contact failure. These are extremely hazardous
and may result in electric shock and/or improper function of the robot system.
■
When removing the connector sub plate, make sure to remove all connectors of
the connector plate and the M/C cable. Removing only the connector sub plate
may result in damage to the cables, disconnection, and/or contact failure. These
are extremely hazardous and may result in electric shock and/or improper function
of the robot system.
■
When installing the connector sub plate, be careful not to get the cables caught in
it or bend them forcibly to push into the cover.
Unnecessary strain on cables may result in damage to the cables, disconnection,
and/or contact failure. These are extremely hazardous and may result in electric
shock and/or improper function of the robot system.
When routing the cables, check the cable locations at removing the connector sub
plate. Be sure to place the cables back to their original locations.
Removal
Remove the bolts and then remove the connector sub
plate.
Hexagon socket head cap bolts: 4-M4×10
Be careful not to lose the seal washers and spacers.
Installation
Install the connector sub plate to the Manipulator.
Hexagon socket head cap bolts: 4-M4×10
Tightening Torque: 4.0
±
0.2 N·m
Be careful not to get the cables caught between the cover and the Manipulator body.
NOTE
NOTE
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...