Maintenance 4. Cable Unit
C12 Rev.3
133
56.
Install the battery board fixing plate.
Hexagon socket head cap bolts: 2-M4x10
Tightening torque: 4.0
±
0.2 N·m
57.
Connect the battery connectors.
58.
Install the battery to the battery box.
59.
Pass the Joint #1 timing belt through the cable.
60.
Use cable brackets (C1) to fix the cables to the base cable fixing plate.
Wrap the cables with the attached silicone sheet.
Use a cable bracket to fix the wrapped silicone sheet.
Hexagon socket head cap bolts: 2-M3
×
6
Tightening torque: 2.0
±
0.1 N·m