Setup & Operation 5. Motion Range
C12 Rev.3
53
5.1.5 Max. Pulse Range of Joint #5
Pulse values in clockwise direction are positive (+) and values in counterclockwise direction
are negative (
-
).
Arm #5
0 pulse position
−
4915350 pulse
+4915350 pulse
+
135
°
-
135
°
.
5.1.6 Max. Pulse Range of Joint #6
From the angle of arm end, clockwise pulse values are positive (+) and counterclockwise
pulse values are negative (
-
).
Arm #6
0 pulse position
+6553800 pulse
−
6553800 pulse
+360
°
-
360
°