Maintenance 3. Covers
102
C12 Rev.3
3.11 Connector Plate
3.11.1 M/C Cable Backward
CAUTION
■
Do not remove the connector plate forcibly. It may result in damage to the cables,
disconnection, and/or contact failure. These are extremely hazardous and may
result in electric shock and/or improper function of the robot system.
■
When installing the connector plate, be careful not to get the cables caught in it or
bend them forcibly to push into the cover.
Unnecessary strain on cables may result in damage to the cables, disconnection,
and/or contact failure. These are extremely hazardous and may result in electric
shock and/or improper function of the robot system.
When routing the cables, check the cable locations at removing the connector
plate. Be sure to place the cables back to their original locations.
Removal
1.
Remove the fan.
For details, refer to
Maintenance 15.
Replacing the Fan.
2.
Remove the bolts on the heat sink
Hexagon socket head cap bolts: 4-M4×15
3.
Remove the heat sink.
For cleanroom model, remove the gasket between the heat
sink and the connecter plate.
4.
Remove the bolts, and then remove the connecter plate. and
the base rear gasket.
Hexagon socket head cap bolts: 11-M4×10
The gasket has the spacers. Be careful not to lose them.
NOTE
NOTE
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...