Maintenance 5. Joint #1
C12 Rev.3
177
Removal: Joint #1 Reduction gear unit (M/C cable downward)
CAUTION
■
This procedure has possibility of hands and fingers being caught and/or damage
or malfunction to the Manipulator. Be very careful when performing
maintenance.
■
Do not loosen the bolts while the Arm #2 is not tilted.
It may cause the belt come off and the Arm #2 falls down, and it is extremely
hazardous. Be sure to do the Removal steps (1) and (2) in
Maintenance 6.1 Joint
#2 - Replacing the Motor
before removing the motor.
■
When removing the Arm #1, there must be two or more people to work on it so
that at least one of them can support the arm while the others are removing the
bolts. Removing the bolts without supporting the arm may result in the arm
falling, bodily injury, and/or malfunction of the robot system.
1.
Remove the following parts.
Connector plate
Connector
Brake power supply
For details, refer to
Maintenance 5.2.3 Joint #1 - Replacing the Timing Belt (M/C Cable Downward)
,
Removal steps (1) to (8).
2.
Remove the ground terminals.
Cross recessed head screws with washer : 9-M4×8, 2-M3×6
3.
Remove the Joint #1 reduction gear unit.
For details, refer to
Maintenance 5.1.2 Joint #1 - Replacing the Reduction Gear Unit (M/C Cable
Backward)
, Removal steps (4) to (14).
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...