Maintenance 3. Covers
C12 Rev.3
95
Installation
1.
Insert the connectors.
RJ45 connector:
Insert the RJ45 connector to the connector on the cover.
F-sensor connector:
Insert the metallic connector to the connector on the cover.
2.
Install the Arm #4 side cover to the Manipulator.
Cross recessed truss head small screws: 7-M4×10 (one side)
Tightening torque: 0.9
±
0.1 N·m
Be careful not to get the cables caught between the cover
and the Manipulator body.
When replacing the cover, attach the electrical shock
warning label and other labels to the places indicated in
the photos.
NOTE