Maintenance 4. Cable Unit
C12 Rev.3
113
25.
Remove the Arm #1 cable brackets (C1: 2 pieces) and cable
protection tube.
Hexagon socket head cap bolts: 4-M3
×
6
26.
Remove the Arm #1 cable brackets (C2 and S2: one each) and cable
protection tube.
Hexagon socket head cap bolts: 2-M3
×
6 (C2)
2-M4
×
10 (S2)
27.
Remove the Arm #2 cable bracket (C2) and cable protection tube.
Hexagon socket head cap bolts: 2-M3
×
6
28.
Remove the Arm #2 cable fixing plate.
Hexagon socket head cap bolts: 2-M4
×
10
29.
Cut off the wire tie that binds the cable protection coils inside the
Arm #2.
Summary of Contents for C12 Series