Maintenance 4. Cable Unit
C12 Rev.3
125
18.
Use a cable bracket (C4) to fix the cables to the Arm #3 cable fixing
plate 2.
Wrap the cables with the attached silicone sheet.
Use a cable bracket to fix the wrapped silicone sheet.
Hexagon socket head cap bolts: 2-M3
×
6
Tightening torque: 2.4
±
0.1 N·m
19.
Install the Arm #3 cable fixing plate 2 to the Arm #3.
Hexagon socket head cap bolts: 2-M4
×
10
Tightening torque: 4.0
±
0.2 N·m
20.
Use the cable protection spring to bind cables at the Arm #3 cable
fixing plate 1.
Type of wire tie: AB100
Number of wire ties: 4
21.
Install the Arm #3 cable fixing plate 1 to the Arm #3.
Hexagon socket head cap bolts: 2-M4
×
10
Tightening torque: 4.0
±
0.2 N·m
When installing the Arm #3 cable fixing plate, see the picture on
the right side and push the plate to the arrow direction.
NOTE