ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-65
P2-33
▲
AUT3 Semi-Auto Inertia Adjustment
Address: 0242H
0243H
Operation
Interface:
Panel/Software
Communication
Related Section: N/A
Default:
0
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 1
Data Size: 16-bit
Format: Decimal
Settings:
Semi-auto
Setting:
1: It means the inertia estimation in semi-auto mode is
completed. The inertia value can be accessed via P1-37.
0: 1. When the display is 0, it means the inertia adjustment is
not completed and is adjusting.
2. When the setting is 0, it means the inertia adjustment is
not completed and is adjusting.
P2-34
SDEV The Condition of Overspeed Warning
Address: 0244H
0245H
Operation
Interface:
Panel/Software
Communication
Related Section: 6.2.5
Default:
5000
Control
Mode:
S
Unit: r/min
Range: 1 ~ 6000
Data Size: 16-bit
Format: Decimal
Settings: The setting of over speed warning in servo drive error display
(P0-01)
Semi-auto setting
Reserved
Not in use