Chapter 7 Parameters
ASDA-B2
7-44
Revision May, 2018
1. Speed Command: It is the command issued by the user
(without acceleration / deceleration), not the one of front end
speed circuit.
Source: Analog voltage and register
2. Feedback Speed: The actual speed of the motor and have gone
through the filter.
3. Obtain the absolute value
4. DO.SP_OK will be ON when the absolute value of speed error is
smaller than P1-47, or it will be OFF. If P1-47 is 0, DO.SP_OK is
always OFF.
P1-48
Reserved
Address: 0160H
0161H
P1-49
Reserved
Address: 0162H
0163H
P1-50
Reserved
Address: 0164H
0165H
P1-51
Reserved
Address: 0166H
0167H
P1-52
RES1 Regenerative Resistor Value
Address: 0168H
0169H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.6.3
Default:
See the table below
Control
Mode:
ALL
Unit: Ohm
Range: 10 ~ 750
Data Size: 16-bit
Format: Decimal
Settings:
Model
Default
750 W models
100
Ω
1 kW to 3 kW models
40
Ω