ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-17
P0-13
★
CM5 Status Monitor Register 5
Address: 001AH
001BH
Operation
Interface:
Panel/Software
Communication
Related Section:
4.3.5
Default:
-
Control
Mode:
ALL
Unit: -
Range: -
Data Size: 32-bit
Format: Decimal
Settings: The setting value which is set by P0-21 should be monitored via
P0-13.
P0-14
Reserved
Address: 001CH
001DH
P0-15
Reserved
Address: 001EH
001FH
P0-16
Reserved
Address: 0020H
0021H
P0-17
CM1A Status Monitor Register 1 Selection
Address: 0022H
0023H
Operation
Interface:
Panel/Software
Communication
Related Section: N/A
Default:
0
Control
Mode:
-
Unit: -
Range: 0 ~ 18
Data Size: 16-bit
Format: Decimal
Settings:
Please refer to P0-02 for its setting value.
For example:
If P0-17 is set to 07, then reading P0-09 means reading “Motor
speed (r/min)”.