Chapter 7 Parameters
ASDA-B2
7-14
Revision May, 2018
P0-03
MON Analog Monitor Output
Address: 0006H
0007H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.6.3
Default:
00
Control
Mode:
ALL
Unit: -
Range: 00 ~ 77
Data Size: 16-bit
Format: Hexadecimal
Settings:
NOTE
Please refer to parameter P1-04, P1-05 for proportional setting
of analog output voltage.
For example: P0-03 = 01 (MON1 is the analog output of motor
speed; MON2 is the analog output of motor torque)
MON1 output voltage
8
.
(unit
:
Volts)
MON2 output voltage
8
.
(unit: Volts)
P0-04
■
Reserved
Address: 0008H
0009H
MON1,
MON2
Setting
Value
Description
0
Motor speed (+/-8 Volts/Max. speed)
1
Motor torque (+/-8 Volts/Max. torque)
2
Pulse command frequency (+8 Volts
/
4.5Mpps)
3
Speed command (+/-8 Volts/ Max. speed
command)
4
Torque command (+/-8 Volts/Max. torque
command)
5
VBUS voltage (+/-8 Volts
/
450V)
6 Reserved
7 Reserved