ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-45
P1-53
RES2 Regenerative Resistor Capacity
Address: 016AH
016BH
Operation
Interface:
Panel/Software Communication
Related Section:
6.6.3
Default:
See the table below
Control
Mode:
ALL
Unit: Watt
Range: 30 ~ 3000
Data
Size:
16-bit
Format: Decimal
Settings:
Model
Default
750 W models
60 W
1 kW to 3 kW models
60 W
P1-54
PER Position Completed Range
Address: 016CH
016DH
Operation
Interface:
Panel/Software
Communication
Related Section:
Table 7.2
Default:
1600
Control
Mode:
PT
Unit: pulse
Range: 0 ~ 1280000
Data Size: 32-bit
Format: Decimal
Settings: In position mode (PT), if the deviation pulse number is smaller
than the setting range (the setting value of parameter P1-54),
DO.TPOS is ON.
P1-55
MSPD Maximum Speed Limit
Address: 016EH
016FH
Operation
Interface:
Panel/Software
Communication
Related Section: N/A
Default:
rated speed
Control
Mode:
ALL
Unit: r/min
Range: 0 ~ Max. speed
Data Size: 16-bit
Format: Decimal
Settings: The default of the max. speed of servo motor is set to the rated
speed.