Chapter 7 Parameters
ASDA-B2
7-16
Revision May, 2018
P0-10
★
CM2 Status Monitor Register 2
Address: 0014H
0015H
Operation
Interface:
Panel/Software
Communication
Related Section:
4.3.5
Default:
-
Control
Mode:
ALL
Unit: -
Range: -
Data Size: 32-bit
Format: Decimal
Settings: The setting value which is set by P0-18 should be monitored via
P0-10. Set P0-02 to 24, the panel displays “VAR-2” first, and then
shows the content of P0-10.
P0-11
★
CM3 Status Monitor Register 3
Address: 0016H
0017H
Operation
Interface:
Panel/Software
Communication
Related Section:
4.3.5
Default:
-
Control
Mode:
ALL
Unit: -
Range: -
Data Size: 32-bit
Format: Decimal
Settings: The setting value which is set by P0-19 should be monitored via
P0-11. Set P0-02 to 25, the panel displays “VAR-3” first, and then
shows the content of P0-11.
P0-12
★
CM4 Status Monitor Register 4
Address: 0018H
0019H
Operation
Interface:
Panel/Software
Communication
Related Section:
4.3.5
Default:
-
Control
Mode:
ALL
Unit: -
Range: -
Data Size: 32-bit
Format: Decimal
Settings: The setting value which is set by P0-20 should be monitored via
P0-12. Set P0-02 to 26, the panel displays “VAR-4” first, and then
shows the content of P0-12.