Chapter 7 Parameters
ASDA-B2
7-8
Revision May, 2018
Planning of Digital Input / Output and Output Setting Parameter
Parameter Abbr.
Function
Default Unit
Control Mode Related
Section
PT S T
P2-09 DRT
DI
Debouncing
Time
2 2ms
O
O
O -
P2-10 DI1
DI1
Functional Planning
101
N/A
O O O
Table
7.1
P2-11
DI2 DI2 Functional Planning
104
N/A
O O O
Table
7.1
P2-12
DI3 DI3 Functional Planning
116
N/A
O O O
Table
7.1
P2-13
DI4 DI4 Functional Planning
117
N/A
O O O
Table
7.1
P2-14
DI5 DI5 Functional Planning
102
N/A
O O O
Table
7.1
P2-15
DI6 DI6 Functional Planning
22
N/A
O O O
Table
7.1
P2-16
DI7 DI7 Functional Planning
23
N/A
O O O
Table
7.1
P2-17
DI8 DI8 Functional Planning
21
N/A
O O O
Table
7.1
P2-36
DI9 DI9 Functional Planning
0
N/A
O O O
Table
7.1
P2-18
DO1 DO1 Functional Planning
101
N/A
O O O
Table
7.2
P2-19
DO2 DO2 Functional Planning
103
N/A
O O O
Table
7.2
P2-20
DO3 DO3 Functional Planning
109
N/A
O O O
Table
7.2
P2-21
DO4 DO4 Functional Planning
105
N/A
O O O
Table
7.2
P2-22
DO5 DO5 Functional Planning
7
N/A
O O O
Table
7.2
P2-37
DO6 DO6 Functional Planning
7
N/A
O O O
Table
7.2
P1-38
ZSPD Zero Speed Range Setting
100
0.1
r/min
O O O
Table
7.2
P1-39
SSPD Target Motor Detection Level
3000 r/min O O O
Table
7.2
P1-42
MBT1 Enable Delay Time of Brake
0
ms
O
O O
6.5.5
P1-43
MBT2 Disable Delay Time of Brake
0
ms
O
O O
6.5.5
P1-47 SCPD
Speed Reached (DO
:
SP_OK)
Range
10 r/min O
Table
7.2