ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-31
P1-11
SP3
Internal Speed Command 3 / Internal
Speed Limit 3
Address: 0116H
0117H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.3.1
Default:
3000
Control
Mode:
S, T
Unit: 0.1r/min
Range: -50000 ~ +50000
Data Size: 32-bit
Format: Decimal
Example 120 = 12 r/min
Settings: Internal Speed Command 3: The setting of the third internal speed
command.
Internal Speed Limit 3: The setting of the third internal speed limit.
P1-12
TQ1
Internal Torque Command 1 / Internal
Torque Limit 1
Address: 0118H
0119H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.4.1
Default:
100
Control
Mode:
T, P&S
Unit: %
Range: -300 ~ +300
Data Size: 16-bit
Format: Decimal
Settings: Internal Torque Command
1: The setting of the first internal torque
command.
Internal Torque Limit 1: The setting of the first internal torque limit.