Chapter 7 Parameters
ASDA-B2
7-42
Revision May, 2018
P1-45
▲
GR2 Gear Ratio (Denominator) (M)
Address: 015AH
015BH
Operation
Interface:
Panel/Software
Communication
Related Section:
Section 6.2.3
Default:
10
Control
Mode:
PT
Unit: pulse
Range: 1 ~ (2
31
-1)
Data Size: 32-bit
Format: Decimal
Settings: If the setting is wrong, the servo motor will easily have sudden
unintended acceleration.
Please follow the rules for setting:
The setting of pulse input:
Pulse
input
f1
N
M
Position
command
f2
f2 = f1 x
N
M
Range of command pulse input: 1 / 50
<
Nx / M
<
25600 (x = 1, 2,
3, 4)
NOTE
The setting value cannot be changed when Servo ON in PT
mode.
P1-46
▲
GR3 Pulse Number of Encoder Output
Address: 015CH
015DH
Operation
Interface:
Panel/Software
Communication
Related Section: N/A
Default:
2500
Control
Mode:
ALL
Unit: pulse
Range: 4 ~ 40000
Data Size: 32-bit
Format: Decimal
Settings: This parameter is used to set the number of single-phase pulse
output per revolution.