Maintenance
Status messages
104
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
BUS software error
A software error of the servo unit leads to pulse inhibit of the controller.
Bit-Nr.
Meaning
0
1: watchdog error (PI)
1
1: task length exceeded (CI)
2
1: power unit not recognized at all
3 ... 7
reserved
8
1: incompatible hardware version (PI)
9
1: incompatible software version (PI)
10
1: wrong motor type (PI)
11
1: wrong power unit type (PI)
12
1: error when reading data memory (PI)
13 ... 15
reserved
PI (pulse inhibit)
CI (controller inhibit)
initialisation error of BUS I/O components
An initialisation error of the servo unit leads to pulse inhibit of the controller.
Bit no.
Meaning
0
1: error data D502 digital motherboard
1
1: error command data D502 digital motherboard
2
1: error data D504 digital motherboard
3
1: error command data D504 digital motherboard
4
1: error data D503 digital motherboard
5
1: error command data D503 digital motherboard
6
1: error data D101 analog motherboard
7
1: error command data D101 analog motherboard
8
1: error data D102 analog motherboard
9
1: error command data D102 analog motherboard
10
1: error data D103 analog motherboard
11
1: error command data D103 analog motherboard
12
1: error data D104 analog motherboard
13
1: error command data D104 analog motherboard
14 ... 15
reserved
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...