Set value adaptation
Parameters
Controller BUS 6 T
93
Baumüller Nürnberg GmbH
5.94017.06
7.9 Set value adaptation
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
set value adaptation
32922
n
set
main spindle offset
- 100.0000 ... 100.0000
rpm
32923
n
set
C axis offset
- 100.0000 ... + 100.0000
rpm
32924
M
set
offset
- 2 ... + 2
%
0
32925
n
set
-max MSP
- 100.0000 ... 12000.0000
rpm
32926
M limitation analog
0 ... 2
0
Parameter description:
n
set
main spindle offset
n
set
C axis offset
M
set
offset
With analog set value input these parameters serve for offset correction.
n
set
max MSP
This parameter sets the maximum speed by
±
10 V at X2:1/2.
±
10 V
⇔
±
n
soll
max MSP (rpm)
min. value:
100 rpm
max. value:
n
max
(ID no. 113) + 200 rpm
M limitation analog
This parameter sets the torque threshold (ID no. 32818 = 0).
Value
Meaning
0
symmetric limitation of both torque directions
X2:7=+10 V or -10 V
torque limitation positive = +100 %
torque limitation negative = -100 %
torque limitation bipolar = 100 %
1
not symmetric
X2:7=+10 V
torque limitation positive = +100 %
torque limitation negative = 0 %
torque limitation bipolar = 100 %
X2:7=-10 V
torque limitation positive = 0 %
torque limitation negative = -100 %
torque limitation bipolar = 100 %
2
torque limitations the same as set digital value
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...