Parameters
Basic settings
58
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
Parameter description
temperature model
This parameter selects whether the operation is to take place with or without temperature
correction.
Value
Meaning
0
inactive
1
active
application speed for motor nominal speed
The constant torque of machine tools can be increased from 0 ... n
N
to 0 ... n
max
. The
selected application speed must, however, not be smaller than the nominal motor speed.
rotor time constant
ττττ
R
Asynchronous motor:
τ
σ
R
h
L
L
R
=
′ +
′
2
2
L
2
σ
= inductance
L
h
= main inductance
R
2
´= resistance
Synchronous motor:
typical value: 10 ms ... 50 ms