Parameters
Parameter set 1
84
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
7.5 Parameter set 1
7.5.1 Velocity and ramp function generator
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
velocity and ramp function generator
4132
set velocity value
-12000.0000 ... 12000.0000
rpm
0
(
)
4139
polarity of set velocity value
0
4134
positive velocity limit value
0.0000 ... 12000.0000
rpm
4135
negative velocity limit value
0.0000 ... 12000.0000
rpm
4187
bipolar velocity limit value
0.0000 ... 12000.0000
rpm
40
actual velocity value
-12000.0000 ... 12000.0000
rpm
36921
ramp function generator
0 ... 1
0
36922
ramp-up time
0.010 ... 60.000
s
0.01
36923
ramp-down time
0.010 ... 60.000
s
0.01
6.5.2 Rounding generator and torque
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
rounding generator and torque
36919
rounding generator
0 ... 1
0
36920
rounding generator time
10.0 ... 6000.0
ms
10
4176
set torque value for M control
-100.0 ... 100.0
%
0
4181
polarity of set torque value
0
4178
positive torque limit value
0.0 ... 100.0
%
100
(
)
4179
negative torque limit value
-100.0 ... 0
%
-100
(
)
4188
bipolar torque limit value
0.0 ... 100.0
%
100
(
)
84
actual torque value
-100.0 ... 100.0
%
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...